Anatomy of a report

What every report contains

Test results are only useful if they can be traced, reviewed and matched to a specification. Every report we issue carries the same core information.

01

Project and sample identification

Project name, sample location, the date sampled and by whom, and the material being tested — so a result can always be traced back to where it came from.

02

Test method

The AASHTO, ASTM or GDT designation the test was performed under, so the result can be matched against the method your specification calls for.

03

Results and specification comparison

The measured values, and where the specification defines a limit or range, how the result compares against it.

04

Technician and review

Who performed the test and who reviewed it. Work is carried out under the supervision of a Professional Engineer licensed in Georgia.

Reference

The tests, in plain language

What each test measures and why a specification asks for it. Designations match the full scope listed on our Lab Testing page.

Soil testing establishes how a material behaves under load and moisture, and sets the compaction targets the field is held to.

Standard Proctor

AASHTO T99 · ASTM D698 · GDT 7

What it measures
Determines the maximum dry density and optimum moisture content of a soil using a 5.5 lb rammer.
Why it is specified
This result becomes the benchmark field compaction is measured against. When a specification calls for 95% compaction, it means 95% of this laboratory maximum dry density.

Modified Proctor

AASHTO T180 · ASTM D1557

What it measures
The same moisture-density relationship determined with a heavier 10 lb rammer and greater compactive effort.
Why it is specified
Produces a higher maximum dry density and is specified where heavier loading is expected, such as pavement subgrades and structural fill.

Atterberg Limits

AASHTO T89, T90 · ASTM D4318

What it measures
Measures the liquid limit and plastic limit of a fine-grained soil, and the plasticity index derived from them.
Why it is specified
Describes how a soil behaves as moisture changes. High plasticity signals shrink-swell potential, which drives both classification and foundation recommendations.

Particle size and gradation

AASHTO T88 · ASTM D422, D1140 · GDT 4

What it measures
Determines the distribution of particle sizes. Sieving covers the coarse fraction; hydrometer analysis resolves silt and clay sizes passing the No. 200 sieve.
Why it is specified
Gradation governs drainage, compactibility and suitability as fill, and is a required input to soil classification.

Classification (USCS)

ASTM D2487

What it measures
Combines gradation and plasticity results into a group symbol such as CL, SM or GW.
Why it is specified
The shorthand most geotechnical recommendations are written against, so it travels with the material through design and construction.

Moisture content

AASHTO T265 · ASTM D2216

What it measures
The mass of water expressed as a percentage of the dry mass of the soil.
Why it is specified
Underpins nearly every other soil test, and is how field moisture is checked against the proctor optimum before compaction is accepted.

In-place density

AASHTO T310, T191 · ASTM D6938, D1556

What it measures
Measures in-place dry density and moisture, by nuclear gauge or by the sand-cone method.
Why it is specified
Expresses field compaction as a percentage of the laboratory proctor. The nuclear gauge is faster; the sand cone is the referee method when gauge results are questioned.

Volume change

GDT 6

What it measures
Determines the volume change of a soil caused by the absorption and loss of water.
Why it is specified
Identifies materials that will swell and shrink with moisture, which matters for subgrade performance on roadway work.

Example

What a report looks like

A sample compressive strength report, so you know the format and level of detail before the first result arrives. Project details below are illustrative.

Sample report — illustrative only

ASEC - AS Engineering and Consulting LLC

6196 Queen Mill Road SE
Mableton, GA 30126
(770) 410-8172

Compressive Strength
of Concrete Cylinders

AASHTO T22 · ASTM C39

Project
Westside Logistics Center — Building B
Client
Sample Client, Inc.
Location
Mableton, Georgia
Report No.
SAMPLE-2026-0412
Report date
April 2, 2026
Placement
Slab on grade, Grid C4–F8
Mix design
4,000 psi @ 28 days
Specimen type
4 x 8 in. cylinders (ASTM C31)
Sample compressive strength results for four concrete cylinders
SpecimenCastTestedAge (days)Max load (lbf)Strength (psi)% of design
A-103/04/202603/11/2026737,4502,98075%
A-203/04/202603/11/2026738,3303,05076%
A-303/04/202604/01/20262858,0604,620116%
A-403/04/202604/01/20262859,1904,710118%
Strength development

Average of two specimens at each age, against the 4,000 psi design strength.

01,0002,0003,0004,0005,000psi07142128Age (days)4,000 psi design7 days: 3,015 psi3,015 psi28 days: 4,665 psi4,665 psi

Remarks

Specimens cast, transported and cured in accordance with ASTM C31 and stored in the laboratory moist room until tested. Caps conformed to ASTM C1231. All 28-day results exceed the specified design strength of 4,000 psi.

Tested by

Field Technician, ACI Certified

Reviewed by

Laboratory Manager

Under the supervision of a Georgia-licensed PE

Accredited by the AASHTO Accreditation Program (AAP) for the test methods shown, at our Mableton, Georgia laboratory · ASTM C1077 · Results apply only to the specimens tested. This document is a formatting sample prepared for the ASEC website and does not represent an actual project.

Different tests carry different detail. A gradation report, for example, plots the result against the specification band so you can see at a glance whether the material sits inside it.

Sample report — illustrative only

ASEC - AS Engineering and Consulting LLC

6196 Queen Mill Road SE
Mableton, GA 30126

Sieve Analysis
of Aggregate

AASHTO T27 · ASTM C136 · GDT 4*

Project
Paulding County Roadway — Phase 2
Client
Sample Client, Inc.
Material
Graded aggregate base
Sample No.
A-2402-C
Report No.
SAMPLE-2026-0388
Sampled
March 1, 2026
Gradation curve

Percent passing against sieve size, with the specification band shaded.

0204060801001½": 100% passing (band 100–100%)1½"1": 97% passing (band 90–100%)1"¾": 85% passing (band 75–95%)¾"½": 72% passing (band 60–85%)½"No. 4: 48% passing (band 35–65%)No. 4No. 10: 35% passing (band 25–50%)No. 10No. 40: 18% passing (band 12–30%)No. 40No. 200: 8% passing (band 5–15%)No. 200Sieve size — coarse to fine% passing
Percent passing each sieve against the specification band
Sieve% passingSpec bandResult
1½"100100–100Pass
1"9790–100Pass
¾"8575–95Pass
½"7260–85Pass
No. 44835–65Pass
No. 103525–50Pass
No. 401812–30Pass
No. 20085–15Pass

Accredited by the AASHTO Accreditation Program (AAP) for the test methods shown, at our Mableton, Georgia laboratory. *ASEC is not AAP-accredited for methods marked with an asterisk. Results apply only to the sample tested. This document is a formatting sample prepared for the ASEC website and does not represent an actual project.